ABB - Low Voltage Drives ACS880-01-034A-5+B056+J425+K475 - ACS880 AC Drive, 3-380-500V In, 25HP, 34A, Type 12, 1.1 overload, Assistant Industrial, HxWxD 20.67x7.09x12.87 in, Wall, High performance 2-port Ethernet, Ethernet/IP, Modbus/TCP, PROFINET
ABB - Low Voltage Drives

ACS880-01-034A-5+B056+J425+K475

Alternate Item Number: 3AXD50000681259

Contact for Pricing

Overview

The ABB ACS880-01-034A-5+B056+J425+K475 AC drive is a compact, wall-mountable industrial drive designed for 3-phase applications requiring 380-500VAC input. Rated at 25HP (18.5kW) with a continuous current of 34A, this drive delivers precise motor control for pumps, fans, conveyors, and other industrial machinery. Its Type 12 enclosure ensures protection against dust and water ingress, making it suitable for harsh environments. The drive features a 1.1 overload capacity for short-term peak loads and operates at 50Hz frequency. Measuring 20.67 x 7.09 x 12.87 inches, it fits efficiently in space-constrained installations. Advanced communication is built-in with dual-port Ethernet supporting Ethernet/IP, Modbus/TCP, and PROFINET protocols for seamless integration with PLCs and automation systems. The ACS880 series is manufactured in Denmark and is part of ABB’s Low Voltage Drives portfolio, known for energy efficiency and reliability in industrial automation. This specific model, ACS880-01-034A-5+B056+J425+K475, is an Assistant Industrial drive. The drive's dimensions are HxWxD 20.67x7.09x12.87 inches. It is designed for wall mounting. The drive supports high performance with its 2-port Ethernet capability. The communication protocols supported are Ethernet/IP, Modbus/TCP, and PROFINET. The input voltage range is 3-380-500V. The drive's continuous current rating is 34A. The motor power rating is 25HP. The overload capability is 1.1.
  • 25HP (18.5kW) power rating, 34A continuous current, 380-500VAC input
  • Type 12/IP54 enclosure for dust and water resistance in harsh environments
  • 1.1 overload capacity for handling short-term peak loads
  • Dual-port Ethernet with support for Ethernet/IP, Modbus/TCP, and PROFINET
  • Compact dimensions: 20.67 x 7.09 x 12.87 inches, wall-mountable
  • 50Hz frequency operation, manufactured in Denmark by ABB Low Voltage Drives

Specifications

Amerage
34 A
Control Panel
Assistant Industrial
Enclosure Construction (IP rating)
IP55
Enclosure Construction (UL Type)
12
Enclosure UL Type
12
Frame Size
R3
Height
20.67 in
Horsepower
25 HP
Horsepower 10% & 50% Overload/ 1 min
25 HP
Input Phase
3-Phase
IP Rating
IP55
Length
12.87 in
Mounting
Wall
Number of Phases Input
3
Number of Phases Output
3
Options
High performance 2-port Ethernet, Ethernet/IP, Modbus/TCP, PROFINET
Output Current
34 A
Output Current 10% & 50% Overload/ 1 min
34 A
Output Phase
3-Phase
Phases
3-Phase A
Type
ACS880 Drive
UL Enclosure Construction
12
UL Type
12
Voltage
480 V
Voltage Range
380-500 V
Voltage Rating
480 VAC
Weight
22 lb
Width
7.09 IN
Package Dimensions (L x W x H)
12.87 IN x 7.09 IN x 20.67 IN
Package Dimensions (L x W x H)
32.6898 cm x 18.0086 cm x 52.5018 cm
Package Weight (Imperial)
22.000 L
Package Weight (Metric)
9.979 kg
Double plastic fiber optic, Qty 1, 5 meters long

61059113

Double plastic fiber optic, Qty 1, 5 meters long
The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.

FENA-21

The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.
600V Class Iron Core Reactor, Core and Coil, 24 Amps, 0.86 Inductance, 60 Hz

CRX0024DC

600V Class Iron Core Reactor, Core and Coil, 24 Amps, 0.86 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 59 Amps, 0.22 Inductance, 60 Hz

CRX0059BC

600V Class Iron Core Reactor, Core and Coil, 59 Amps, 0.22 Inductance, 60 Hz