ABB - Low Voltage Drives ACS580-0P-088A-2+B058+F255+G310+J429 - ACS580 AC Drive, 3-208-240V In, 30HP, 88A, Type 3R, 1.1 overload, Assistant Bluetooth, HxWxD 50.98x35.98x20.35 in, Packaged with Disconnect
ABB - Low Voltage Drives

ACS580-0P-088A-2+B058+F255+G310+J429

Alternate Item Number: 3AUD0000003046

Contact for Pricing

Overview

The ABB ACS580-0P-088A-2 AC Drive is a compact, high-efficiency variable frequency drive designed for industrial motor control applications. Rated at 30HP (22kW) with a continuous current of 88A, this drive operates on a 3-phase input voltage range of 208-240V at 50/60Hz, making it ideal for North American industrial environments. Its Type 3R enclosure provides IP54 protection against dust and water ingress, ensuring reliable operation in harsh conditions including outdoor installations and washdown areas. Key specifications include a 1.1 overload capacity for temporary peak loads, integrated Assistant Bluetooth connectivity for wireless setup and monitoring via ABB's Drive Assistant app, and a built-in disconnect switch for enhanced safety compliance. The drive measures 50.98 x 35.98 x 20.35 inches (1295 x 914 x 517 mm) and weighs approximately 240 lbs (109 kg), with mounting dimensions compatible with standard industrial enclosures. This drive excels in applications requiring precise speed control for pumps, fans, compressors, and conveyors. Its advanced control algorithms deliver energy savings up to 30% compared to fixed-speed operation, while the integrated safety features meet UL, CSA, and IEC standards. The ACS580-0P-088A-2 is part of ABB's ACS580 series, known for its modular design that simplifies maintenance and reduces downtime. With a UNSPSC code of 39122001 and manufactured in Denmark, this drive combines European engineering with North American voltage compatibility for global industrial applications.
  • 30HP (22kW) output with 88A continuous current rating
  • 208-240V 3-phase input, 50/60Hz operation
  • Type 3R enclosure (IP54) for indoor/outdoor use
  • 1.1 overload capacity for temporary peak loads
  • Integrated Assistant Bluetooth for wireless setup/monitoring
  • Built-in disconnect switch for enhanced safety
  • UL, CSA, and IEC certified for North American markets
  • Compact dimensions: 50.98 x 35.98 x 20.35 inches (1295 x 914 x 517 mm)
  • Energy savings up to 30% vs. fixed-speed operation
  • UNSPSC code 39122001, manufactured in Denmark

Specifications

Amerage
88 A
Control Panel
Assistant Bluetooth
Current Rating
88A
Enclosure UL Type
3R
Frame Size
R5
Height
50.98 in
Horsepower
30 HP
Horsepower 10% & 50% Overload/ 1 min
30 HP
Input Phase
3-Phase
IP Rating
n/a
Length
20.35 in
Mounting
Packaged with Disconnect
NEMA Rating
Type 3R
Number of Phases Input
3
Number of Phases Output
3
Options
Door interlock circuit breaker (standard rated KAIC) Manual bypass with selector switch & interlock
Output Current
88 A
Output Current 10% & 50% Overload/ 1 min
88 A
Output Phase
3-Phase
Phases
3-Phase A
Series
ACS580
Size
50.98x35.98x20.35 in
Type
ACS580 Drive
UL Enclosure Construction
3R
UL Type
3R
Voltage
240 V
Voltage Range
208-240 V
Voltage Rating
3-208-240V
Voltage Rating
240 Vac
Weight
445 lb
Width
35.98 in
Double plastic fiber optic, Qty 1, 5 meters long

61059113

Double plastic fiber optic, Qty 1, 5 meters long
The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.

FENA-21

The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.
600V Class Iron Core Reactor, Core and Coil, 24 Amps, 0.86 Inductance, 60 Hz

CRX0024DC

600V Class Iron Core Reactor, Core and Coil, 24 Amps, 0.86 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 59 Amps, 0.22 Inductance, 60 Hz

CRX0059BC