ABB - Low Voltage Drives ACS580-0P-077A-4+B056+J429+K491 - ACS580 AC Drive, 3-380-480V In, 60HP, 77A, Type 12, 1.1 overload, Assistant Bluetooth, HxWxD 42.56x8.39x14.25 in, Packaged with Disconnect, Modbus/TCP, configured for FB adapter 2
ABB - Low Voltage Drives

ACS580-0P-077A-4+B056+J429+K491

Alternate Item Number: 3AXD50000689071

Contact for Pricing

Overview

The ABB ACS580-0P-077A-4+B056+J429+K491 AC Drive delivers precise motor control for industrial automation with a 60HP (77A) output at 380-480V input. This variable frequency drive features a Type 12 NEMA enclosure for indoor protection against dust and water ingress, ensuring reliable operation in harsh environments. The drive includes built-in Assistant Bluetooth connectivity for wireless monitoring and configuration via ABB’s Drive Assistant Mobile app, enabling technicians to adjust parameters and troubleshoot remotely without physical access. Pre-configured for Modbus/TCP communication, it integrates seamlessly with industrial control systems for real-time monitoring and data exchange, supporting Industry 4.0 initiatives. The 1.1 overload capacity provides temporary current handling up to 110% of rated current, protecting motors and connected equipment during transient loads. Packaged with a disconnect switch, the drive simplifies installation and maintenance while meeting safety compliance standards. With compact dimensions of 42.56 x 8.39 x 14.25 inches, it fits standard motor frames and space-constrained control panels. Ideal for applications including pumps, fans, conveyors, and compressors, the ACS580 enhances energy efficiency by optimizing motor speed to match load requirements, reducing power consumption and operational costs. ABB’s proven reliability ensures minimal downtime, making it a dependable choice for facilities prioritizing productivity and sustainability.
  • 60HP (77A) output at 380-480V input for high-power industrial applications
  • Type 12 NEMA enclosure for indoor protection against dust and water
  • Assistant Bluetooth for wireless monitoring and configuration via Drive Assistant Mobile app
  • Pre-configured Modbus/TCP communication for seamless integration with industrial control systems
  • 1.1 overload capacity for temporary current handling up to 110% of rated current
  • Packaged with disconnect switch for simplified installation and safety compliance
  • Compact dimensions (42.56 x 8.39 x 14.25 in) for space-constrained environments

Specifications

Amerage
77 A
Color
Blue
Control Panel
Assistant Bluetooth
Current Rating
77 A
Enclosure UL Type
12
Frame Size
R4
Frequency
50/60 Hz
Height
42.56 in
Horsepower
60 HP
Horsepower 10% & 50% Overload/ 1 min
60 HP
Input Phase
3-Phase
IP Rating
IP55
Length
14.25 IN
Material
Poly
Mounting
Packaged with Disconnect
Nema Rating
Type 12
Number of Phases Input
3
Number of Phases Output
3
Options
Modbus/TCP, configured for FB adapter 2
Output Current
77 A
Output Current 10% & 50% Overload/ 1 min
77 A
Output Phase
3-Phase
Phases
3-Phase A
Series
ACS580
Shipping Depth
20 IN
Shipping Length
55 IN
Shipping Weight
107 LB
Shipping Width
15 IN
Size
42.56x8.39x14.25 in
Type
ACS580 Drive
UL Enclosure Construction
12
UL Type
12
Voltage
480 V
Voltage Range
380-480 V
Voltage Rating
480 VAC
Voltage Rating
380-480 VAC
Weight
60 lb
Width
8.39 in
Package Dimensions (L x W x H)
14.25 IN x 8.39 IN x 42.56 IN
Package Dimensions (L x W x H)
36.195 cm x 21.3106 cm x 108.1024 cm
Package Weight (Imperial)
60.000 L
Package Weight (Metric)
27.216 kg
Double plastic fiber optic, Qty 1, 5 meters long

61059113

Double plastic fiber optic, Qty 1, 5 meters long
The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.

FENA-21

The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.
600V Class Iron Core Reactor, Core and Coil, 24 Amps, 0.86 Inductance, 60 Hz

CRX0024DC

600V Class Iron Core Reactor, Core and Coil, 24 Amps, 0.86 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 59 Amps, 0.22 Inductance, 60 Hz

CRX0059BC