ABB - Electrification SPUV120ACR - The undervoltage release is an electronic module used to open the circuit breaker when the monitored voltage drops below 35-60PERC of its rated value. The undervoltage release "resets" when the monitored voltage is re-established allowing the circuit breaker to reclose (the sealing voltage of the UVR is 60-85PERC of its rated voltage). An undervoltage release trip operation is produced by the MicroVersaTrip½ Plus unit in response to a signal from the undervoltage release module. This allows the trip unit to record, display, distinguish an d comm un icate (in MicroVer saTri p½ PM trip units) that the breaker opening event was due to undervoltage release. Operation of the undervoltage release module will prevent breaker contact closure, i.e. "kiss-free" operation. When energized, the undervoltage release supplies +24 Vdc power to the trip unit to power the display. Field installable. 0ACR Frame Rating Amps 2500
ABB - Electrification

SPUV120ACR

UPC: 783164072648

Contact for Pricing

Overview

The ABB SPUV120ACR undervoltage release module (SKU: SPUV120ACR) is a field-installable electronic module designed for 0ACR frame circuit breakers rated at 2500A. It monitors system voltage and automatically opens the circuit breaker when voltage drops below 35-60% of the rated value, preventing equipment damage from under-voltage conditions. The module resets automatically when voltage returns to 60-85% of the rated value, enabling safe breaker reclosure. It integrates with MicroVersaTrip Plus trip units to log undervoltage events, display trip causes, and communicate trip reasons in compatible systems. The SPUV120ACR prevents breaker contact closure ('kiss-free' operation) until voltage stabilizes, enhancing system safety. When energized, it supplies +24V DC power to the trip unit display. The module is field-installable without requiring breaker removal, supporting critical protection in industrial power distribution systems where voltage stability is essential. Compatible with ABB 0ACR frame circuit breakers.
  • Monitors system voltage and trips circuit breaker at 35-60% of rated value
  • Automatic reset when voltage returns to 60-85% of rated value
  • Integrates with MicroVersaTrip Plus trip units for event logging and communication
  • Prevents breaker contact closure ('kiss-free' operation) until voltage stabilizes
  • Supplies +24V DC power to trip unit display when energized

Specifications

Current Rating
2500 A
Special Features
The undervoltage release is an electronic module used to open the circuit breaker when the monitored voltage drops below 35-60PERC of its rated value. The undervoltage release "resets" when the monitored voltage is re-established allowing the circuit breaker to reclose (the sealing voltage of the UVR is 60-85PERC of its rated voltage). An undervoltage release trip operation is produced by the MicroVersaTrip½ Plus unit in response to a signal from the undervoltage release module. This allows the trip unit to record, display, distinguish an d comm un icate (in MicroVer saTri p½ PM trip units) that the breaker opening event was due to undervoltage release. Operation of the undervoltage release module will prevent breaker contact closure, i.e. "kiss-free" operation. When energized, the undervoltage release supplies +24 Vdc power to the trip unit to power the display. Field installable. 0ACR Frame Rating Amps 2500
Standard
E57253
Voltage Rating
480 AC
Package Dimensions (L x W x H)
12 IN x 6 IN x 3 IN
Package Dimensions (L x W x H)
30.48 cm x 15.24 cm x 7.62 cm
Package Weight (Imperial)
0.026 L
Package Weight (Metric)
0.012 kg
The undervoltage release is an electronic module used to open the circuit breaker when the monitored voltage drops below 35-60PERC of its rated value. The undervoltage release "resets" when the monitored voltage is re-established allowing the circuit breaker to reclose (the sealing voltage of the UVR is 60-85PERC of its rated voltage). An undervoltage release trip operation is produced by the MicroVersaTrip Plus unit in response to a signal from the undervoltage release module. This allows the trip unit to record, display, distinguish an d comm un icate (in MicroVer saTri p PM trip units) that the breaker opening event was due to undervoltage release. Operation of the undervoltage release module will prevent breaker contact closure, i.e. "kiss-free" operation. When energized, the undervoltage release supplies +24 Vdc power to the trip unit to power the display. Field installable. 5DCR Frame Rating Amps 2500

SPUV125DCR

The undervoltage release is an electronic module used to open the circuit breaker when the monitored voltage drops below 35-60PERC of its rated value. The undervoltage release "resets" when the monitored voltage is re-established allowing the circuit breaker to reclose (the sealing voltage of the UVR is 60-85PERC of its rated voltage). An undervoltage release trip operation is produced by the MicroVersaTrip Plus unit in response to a signal from the undervoltage release module. This allows the trip unit to record, display, distinguish an d comm un icate (in MicroVer saTri p PM trip units) that the breaker opening event was due to undervoltage release. Operation of the undervoltage release module will prevent breaker contact closure, i.e. "kiss-free" operation. When energized, the undervoltage release supplies +24 Vdc power to the trip unit to power the display. Field installable. 5DCR Frame Rating Amps 2500
MS116/132 UVR, 415VAC

UA1-415

MS116/132 UVR, 415VAC
The undervoltage release is an electronic module used to open the circuit breaker when the monitored voltage drops below 35-60PERC of its rated value. The undervoltage release "resets" when the monitored voltage is re-established allowing the circuit breaker to reclose (the sealing voltage of the UVR is 60-85PERC of its rated voltage). An undervoltage release trip operation is produced by the MicroVersaTrip½ Plus unit in response to a signal from the undervoltage release module. This allows the trip unit to record, display, distinguish an d comm un icate (in MicroVer saTri p½ PM trip units) that the breaker opening event was due to undervoltage release. Operation of the undervoltage release module will prevent breaker contact closure, i.e. "kiss-free" operation. When energized, the undervoltage release supplies +24 Vdc power to the trip unit to power the display. Field installable. 8DCR Frame Rating Amps 1600

SPUV048DCR

The undervoltage release is an electronic module used to open the circuit breaker when the monitored voltage drops below 35-60PERC of its rated value. The undervoltage release "resets" when the monitored voltage is re-established allowing the circuit breaker to reclose (the sealing voltage of the UVR is 60-85PERC of its rated voltage). An undervoltage release trip operation is produced by the MicroVersaTrip½ Plus unit in response to a signal from the undervoltage release module. This allows the trip unit to record, display, distinguish an d comm un icate (in MicroVer saTri p½ PM trip units) that the breaker opening event was due to undervoltage release. Operation of the undervoltage release module will prevent breaker contact closure, i.e. "kiss-free" operation. When energized, the undervoltage release supplies +24 Vdc power to the trip unit to power the display. Field installable. 8DCR Frame Rating Amps 1600
MS116/132 UVR, 208VAC

UA1-208

MS116/132 UVR, 208VAC
The undervoltage release is an electronic module used to open the circuit breaker when the monitored voltage drops below 35-60PERC of its rated value. The undervoltage release "resets" when the monitored voltage is re-established allowing the circuit breaker to reclose (the sealing voltage of the UVR is 60-85PERC of its rated voltage). An undervoltage release trip operation is produced by the MicroVersaTrip½ Plus unit in response to a signal from the undervoltage release module. This allows the trip unit to record, display, distinguish an d comm un icate (in MicroVer saTri p½ PM trip units) that the breaker opening event was due to undervoltage release. Operation of the undervoltage release module will prevent breaker contact closure, i.e. "kiss-free" operation. When energized, the undervoltage release supplies +24 Vdc power to the trip unit to power the display. Field installable. 0ACR Frame Rating Amps 2500

SPUV240ACR

The undervoltage release is an electronic module used to open the circuit breaker when the monitored voltage drops below 35-60PERC of its rated value. The undervoltage release "resets" when the monitored voltage is re-established allowing the circuit breaker to reclose (the sealing voltage of the UVR is 60-85PERC of its rated voltage). An undervoltage release trip operation is produced by the MicroVersaTrip½ Plus unit in response to a signal from the undervoltage release module. This allows the trip unit to record, display, distinguish an d comm un icate (in MicroVer saTri p½ PM trip units) that the breaker opening event was due to undervoltage release. Operation of the undervoltage release module will prevent breaker contact closure, i.e. "kiss-free" operation. When energized, the undervoltage release supplies +24 Vdc power to the trip unit to power the display. Field installable. 0ACR Frame Rating Amps 2500
The undervoltage release is an electronic module used to open the circuit breaker when the monitored voltage drops below 35-60PERC of its rated value. The undervoltage release "resets" when the monitored voltage is re-established allowing the circuit breaker to reclose (the sealing voltage of the UVR is 60-85PERC of its rated voltage). An undervoltage release trip operation is produced by the MicroVersaTrip½ Plus unit in response to a signal from the undervoltage release module. This allows the trip unit to record, display, distinguish an d comm un icate (in MicroVer saTri p½ PM trip units) that the breaker opening event was due to undervoltage release. Operation of the undervoltage release module will prevent breaker contact closure, i.e. "kiss-free" operation. When energized, the undervoltage release supplies +24 Vdc power to the trip unit to power the display. Field installable. 4DCR Frame Rating Amps 1600

SPUV024DCR

The undervoltage release is an electronic module used to open the circuit breaker when the monitored voltage drops below 35-60PERC of its rated value. The undervoltage release "resets" when the monitored voltage is re-established allowing the circuit breaker to reclose (the sealing voltage of the UVR is 60-85PERC of its rated voltage). An undervoltage release trip operation is produced by the MicroVersaTrip½ Plus unit in response to a signal from the undervoltage release module. This allows the trip unit to record, display, distinguish an d comm un icate (in MicroVer saTri p½ PM trip units) that the breaker opening event was due to undervoltage release. Operation of the undervoltage release module will prevent breaker contact closure, i.e. "kiss-free" operation. When energized, the undervoltage release supplies +24 Vdc power to the trip unit to power the display. Field installable. 4DCR Frame Rating Amps 1600

Frequently Asked Questions about ABB - Electrification

What industries and applications are Jokab Safety products used for?

Jokab Safety products are specifically designed for machine safety applications across multiple critical industrial sectors, including Food and Beverage, Packaging, and Material Handling industries. Their safety solutions cover a wide range of machine safeguarding needs, such as safety light guards, safety controllers, safety relays, safety edges, safety mats, and two-hand control devices that protect personnel and equipment in complex industrial automation environments.

What technical support does Jokab Safety offer?

Jokab Safety offers comprehensive technical support through multiple channels, including a dedicated technical support phone line at (888) 385-1221 (Option 1) and email support at [email protected]. For advanced technical assistance, customers can contact their specialized Jokab Tech Support at (519) 982-0976 or email [email protected]. Additionally, they provide product specialist support through Jeff Leslie, who can be reached at (519) 982-0976, offering in-depth application and technical guidance.

What are the main product lines offered by Jokab Safety?

Jokab Safety offers a comprehensive range of machine safety products including safety light guards (Orion), safety controllers (Pluto), safety relays (Sentry), safety edges, safety contact mats, safety locks (Gkey), and safety sensors with OSSD and DYNlink interfaces. Their product lines are specifically designed for industrial applications in food and beverage, packaging, and material handling industries, providing robust safety solutions for machine guarding and personnel protection.

What are the key features of Jokab Safety products?

Jokab Safety products offer comprehensive industrial safety solutions with key features including: highest safety certification levels (up to PL e/Cat 4), extensive fault detection, multiple safety device types (optical safety devices, pressure sensitive devices, sensors, switches, locks, emergency stops), and innovative DYNlink technology that reduces cable requirements and simplifies installation. Their products are certified, verified, and compatible with major industrial automation systems like B&R, featuring easy M12 connector connections and a wide range of adapters to streamline safety implementation.

What certifications and standards do ABB - Electrification products comply with?

ABB - Electrification products comply with a comprehensive range of international certifications and standards, including UL (United States), CSA (Canada), CE (European Community), UKCA (United Kingdom), EAC (Russia), and C-Tick (Australia & New Zealand). Our products meet critical international standards such as IEC 60947 series for low-voltage switchgear, functional safety standards EN 61800-5-2 and ISO 13849-1, and marine classification standards from Bureau Veritas, DNV, and Lloyd's Register of Shipping.

What industries and applications are ABB - Electrification products used for?

ABB - Electrification products are engineered for critical applications across multiple industries, including Energy, Oil & Gas, Manufacturing, Power Generation, HVAC, Marine, Food & Beverage, Mining, Pulp & Paper, Water Treatment, and Automotive. Their solutions cover essential electrical infrastructure needs such as switchgear, power distribution systems, circuit protection, digital control technologies, and drive systems designed for high-reliability environments with a strong focus on sustainability, efficiency, and safety.

What technical support does ABB - Electrification offer?

ABB - Electrification offers comprehensive technical support through multiple channels, including a dedicated technical support hotline at 888-385-1221 (Option 1), available 7:00 a.m. - 5:00 p.m. CST, Monday-Friday. Their support services encompass 24/7/365 emergency services, on-site support, remote monitoring and diagnostics, installation and commissioning, equipment assessments, repair coordination, and multi-vendor technical assistance. Customers can also access resources like personnel safety training, disaster recovery support, and service agreements tailored to their specific electrification needs.

What are the main product lines offered by ABB - Electrification?

ABB - Electrification offers a comprehensive range of electrical distribution and protection products, including circuit monitoring systems, panelboards, switchgear, motor control centers, circuit breakers, softstarters, and power distribution solutions. Key product lines span low and medium voltage applications across utilities, commercial, industrial, healthcare, and manufacturing sectors, with specialized offerings like the ReliaGear® panelboards, SMISSLINE TP bus systems, and Ekip UP protection and metering relays.

What are the key features of ABB - Electrification products?

ABB - Electrification products feature advanced integrated design elements that enhance industrial performance and reliability. Key features include harmonics and EMC design, integrated DC choke, removable terminals for fast installation, USB ports for troubleshooting, and integrated Safe Torque Off (STO) functionality. The products deliver superior motor control capabilities, support both induction and permanent magnet motors, and offer robust operational features like side-by-side mounting without derating and operation at temperatures up to 45°C. Additionally, ABB's Electrification solutions emphasize digital innovation, with technologies like Novolink enabling predictive maintenance, enhanced analytics, and seamless system integration.

What communication protocols do ABB - Electrification products support?

ABB - Electrification products support a comprehensive range of industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, CANopen, DeviceNet, and IEC 61850. These protocols enable flexible connectivity across multiple industrial automation platforms, with support for various network topologies and high-speed data transmission up to 100 Mbps.